DC Inverter Split Type VQ

Cruise

Intelligent & Powerful Air conditioning

The new Cruise DC Inverter AC's are the most energy efficient due to their intelligent operation. Using variable speed DC compressor instead of constant speed compressor and a DC fan motor, the cooling or heating capacity of the airconditioner is automatically varied to suit indoor conditions. This makes Cruise Inverter AC's more economical and efficient to operate while being whisper quiet.

DC Inverter Technology, Turbo Cool, Heating and Cooling & 'I Feel' Remote Control

The DC inverter air conditioner signifies the ability of the unit to continuously regulate its thermal transfer flow by altering the speed of the compressor in response to cooling demand. This results in higher COP, powerful cooling and considerable energy savings of upto 50 % in the long run when compared to conventional split air conditioners.

Cruise

Beauty with Brains

The new Cruise DC inverter's simple and elegant panel has been designed to complement the modern interiors with a minimalist LED display aesthetically positioned in the corner of the indoor unit. An emotionally involving minimalist design to keep you cool and relaxed.

Advantages of Inverter AC compared to Non-Inverter AC:

Energy Saving
After the indoor area approaches the set temperature, Inverter Control adjusts to low capacity operation to maintain this temperature. This makes inverter models more energy-saving than non-inverter models, which must repeatedly start or stop their compressors to maintain the room temperature.

Powerful Operation
Inverter air conditioners operate at maximum capacity as soon as they start up. As a result, the set temperature can be reached more quickly.

Silent and Comfortable
Inverter air conditioners finely adjust capacity according to changes in the outside temperature or the number of people in the room. These give higher comfort levels with low noise operaation than with non-inverter air conditioners.


Variable Capacity Operation
Inverter air conditioners are able to vary their operating capacity. Non-inverter air conditioners can only operate at a fixed capacity.



Cruise

Beauty with Brains

  • Energy-saving function
  • I-Feel Technology
  • Hi Efficiency DC Compressor
  • Receiver Window
  • Sleep & Timer Mode


How does the Inverter Technology Work?

Conventional air conditioners use a compressor that is either working at maximum capacity or switched off periodically, to regulate the temperature of the room. A thermostat is used to measure the ambient air temperature and switch the compressor on when the ambient air temperature is too far from the desired temperature.

An alternate way to meet the varying cooling demand is to vary or 'modulate' the capacity of the compressor. An air conditioner compressor has two components, a mechanical part - the actual compressor, and the electrical part - the motor to drive the compressor. Either of the components can be used to modulate the capacity. The other method is to control the speed of the compressors by various means.

"Inverter" air conditioners use a variable frequency drive to control the speed of the motor and thus the compressor. Conversion energy losses from AC to DC and then back to AC can be as high as 4 - 6% for each conversion step.

Eliminating stop-start cycles increases efficiency, extends the life of components, and helps eliminate sharp fluctuations in the load the air conditioner places on the power supply. Ultimately this makes inverter air conditioners less prone to breakdowns, cheaper to run, and the outdoor compressor is generally quieter than a standard air conditioning unit's compressor..



DC Inverter Wall Mounted Type - Vario Qool
Model Name   CWCVGB-VQ5S123 [1 TR] CWCVGB-VQ5S183 [1.5 TR]
Function Cooling Only Cooling Only
Star Rating 3 3
Cooling Capacity W 3500 5038
Power Consumption (Cooling) W 1090(220~1550) 1640 (470~2450)
Power Supply V / Hz - PH 220-240V / 50Hz / 1Ph 220-240V / 50Hz / 1Ph
Rated Current Cooling (A) 4.8 7.28
ISEER for Cooling W 3.66 3.64
Moisture Removal L/H 1.4 1.8
Indoor Unit
Sound Levels (H/M/L) dB (A) 41/35/29 47/41/35
Airflow Volume (H/M/L) m3/h 600/540/460 850/800/700
Dimensions (W x H x D) mm 845×289×209 970×300×224
Package Dimensions (W x H x D) mm 921×379×281 1041×320×383
Net Weight / Gross Weight kg 11/13 13.5/16.5
Outdoor Unit
Condenser Type Copper Copper
Compressor Type Rotary Rotary
Refrigerant Type   R410A R410A
Air Flow Volume m3/h 1600 2000
Noise Level dB (A) 51 54
Piping Length m 4 4
Liquid Pipe inch φ6/φ9.52 φ6/φ12
Gas Pipe inch 1/4"/3/8" 1/4"/1/2"
Dimensions (W x H x D) mm 710×550×318 899×596×378
Package Dimensions (W x H x D) mm 774×607×351 948×645×420
Net Weight / Gross Weight kg 29.5/31.5 40/43.5
MRP INR 39500 47500
 
*Area of cooling is subject to outdoor ambient temperature of 35°c & for residential purpose only.
**All Specifications are approximate and are subject to change without any prior notice.